The robust Dräger Pac 6500 is your reliable companion in tough conditions. The personal single-gas detector quickly and accurately measures CO, H2S, SO2 or O2 levels. The measurement data can be easily transferred via Bluetooth® to the Dräger Gas Detection Connect system. Fast sensor response and a long-lasting battery enhance safety.

The H<sub>2</sub>S sensor of the Pac 6500 can measure concentrations from 0.4 to 100 ppm.
SafetyPortable Gas Detection8 images
The single-gas monitor with CO sensor.
The single-gas monitor with O<sub>2</sub> sensor.
The Pac 6500 with SO<sub>2</sub> sensor.
With the Dräger Bump Test Station you can carry out functional tests using a test gas cylinder in just a few seconds.
The Pac 6500 can easily handle even extreme conditions
Dräger Pac 6500 Single Gas Detectors
Dräger Pac 6500 Single Gas Detectors

Summary

Product overview

Reliable non-disposable single-gas detection device for CO, H2S, SO2, O2for personal air monitoringRobust design, tolerating extreme conditions

Category

Portable Gas Detection

This page is structured from official Draeger content and reorganized for local B2B navigation.

Product enquiry

Enquire about Dräger Pac 6500

Send your project, quantity or specification request directly from the product page. The lead will be stored in the site CRM and can also be routed to email and Telegram notifications.

Selected productDräger Pac 6500

Specifications

Technical groups extracted from the official Draeger detail page.

Specifications 1

Sensor type
Single-Gas Detector
Measurable gases
CO, O2, H2S, SO2
Number of gases
1
Lifetime
unlimited

Specifications 3

Temperature range (device)
-40°C - 55°C
Battery service life
2 years (24/7)
Air humidity (relative humidity) in %
10% to 90%
Air pressure (hPa)
700 - 1300
Degree of protection (IP class)
IP 68
Weight
106 g

Specifications 4

Changable filter
easy to change from outside / mechanical connection

Specifications 5

ATEX
I M1 Ex ia I Ma II 1G Ex ia IIC T4 Ga (Zone 0)
IECEx
Ex ia I Ma Ex ia IIC T4 Ga
c CSA us
Class I, Zone 0, AEx ia IIC T4 Ga, Class II, Division 1, Group E, F, G

Specifications 6

Name
More information
Carbon monoxide
More information
Hydrogen sulphide
More information
Oxygen
More information
Sulphur dioxide
More information

Specifications 7

Product
Order number
DrägerSensor XXS CO LC
6813210
DrägerSensor XXS H2S LC
6811525
DrägerSensor XXS O2
6810881
DrägerSensor XXS SO2
6810885

Related products

Additional products from the same category.

The Dräger X-am 8000 is equipped with a clear signalling design.
SafetyPortable Gas Detection

Dräger X-am 8000

1- to 7 gas detection devicefor clearance measurementdetection of toxic and combustible gases as well as vapours and oxygen

Dräger Calibration gas and accessories
SafetyPortable Gas Detection

Calibration gas and accessories

Ensures safe operation and functionality of equipmentOffers various calibration gas options.Meets applicable regulations and codes of practice

Easy to use, stand-alone and portable.
SafetyPortable Gas Detection

Dräger Bump Test Station

Function testing for gas detection and warning devicesSimple, cordless and portable

Dräger Catalytic Ex-Sensors Sensors for Portable Gas Detectors
SafetyPortable Gas Detection

Dräger Catalytic Ex-Sensors

monitoring of explosive mixtureshigh poisoning resistance to silicones and H2Scompatible with: X-am familymeasuring range: lower explosion limit up to 100 vol.-%