Back to catalogue
Safety / Portable Gas Detection
Dräger X-am 5000
The Dräger X-am 5000 belongs to a generation of gas detectors, developed especially for personal monitoring applications. This 1- to 5-gas detector reliably measures combustible gases and vapors as well as oxygen and harmful concentrations of toxic gases, organic vapors, Odorant and Amine.








Summary
Product overview
1 to 5 gas detection devicefor personal air monitoringDetects combustible gases and vapours, as well as O2, CO, H2S, NO2, and SO2
Category
Portable Gas Detection
This page is structured from official Draeger content and reorganized for local B2B navigation.
Product enquiry
Enquire about Dräger X-am 5000
Send your project, quantity or specification request directly from the product page. The lead will be stored in the site CRM and can also be routed to email and Telegram notifications.
Highlights
Structured product sections from the official source page.
360° Product View
Interactive or visual section carried over from the official product page.
Specifications
Technical groups extracted from the official Draeger detail page.
Specifications 1
- Measurable gases
- Ex, O2, CO, H2S, NO2, SO2, + (choice out of > 40 sensors)
- Sensorports
- 4
- Number of gases
- 1 - 5
- Sensor technology
- CAT + EC
Specifications 3
- Operation time
- >12h
- Dimensions (W × H × D)
- 4.8x13x4.4 cm
- Weight
- 220 g
- Battery type
- NiMh
- Degree of protection (IP class)
- IP 67
Specifications 5
- ATEX
- I M1 Ex da ia I Ma, II 1G Ex da ia IIC T4/T3 Ga
- IECEx
- Ex da ia I Ma, Ex da ia IIC T4/T3 Ga
- c CSA us
- Class I Div. 1 Group A, B, C, D, E, F, T4/T3 | A/Ex da ia IIC T4/T3 /Ga
- GOST (EAC)
- PO Ex da ia I Ma X 0Ex da ia IIC T4/T3 Ga X
Specifications 6
- Name
- More information
- Acetaldehyde
- More information
- Acetic Acid
- More information
- Acetic acid butyl ester
- More information
- Acetic acid ethenyl ester
- More information
- Acetone
- More information
- Acetylene
- More information
- Ammonia (anhydrous)
- More information
- Ammonia solution 25%
- More information
- Arsine
- More information
- Benzene
- More information
- Bromine (gaseous)
- More information
- Carbon dioxide
- More information
- Carbon monoxide
- More information
- Chlorine
- More information
- Chlorine dioxide
- More information
- Cyclohexane
- More information
- Cyclopentane
- More information
- Diborane
- More information
- Diesel fuel
- More information
- Diethylamine
- More information
- Dimethyl disulfide
- More information
- Dimethyl sulphide
- More information
- Dimethylamine (anhydrous)
- More information
- Epichlorohydrin
- More information
- Ethane
- More information
- Ethanol
- More information
- Ethyl acetate
- More information
- Ethyl ether
- More information
- Ethyl mercaptan
- More information
- Ethylamine
- More information
- Ethylene
- More information
- Ethylene oxide
- More information
- Fluorine
- More information
- Formaldehyde
- More information
- Heptane
- More information
- Hexane
- More information
- Hydrogen
- More information
- Hydrogen cyanide (anhydrous)
- More information
- Hydrogen selenide (as Se) (anhydrous)
- More information
- Hydrogen sulphide
- More information
- i-butene
- More information
- Liquified petroleum gas (L.P.G.)
- More information
- Methane
- More information
- Methanol
- More information
- Methyl mercaptan
- More information
- Methyl methacrylate
- More information
- Methylamine (anhydrous)
- More information
- n-Butane
- More information
- n-Butanol
- More information
- n-Pentane
- More information
- Nitric oxide
- More information
- Nitrogen dioxide
- More information
- Nonane
- More information
- Octane
- More information
- Oxygen
- More information
- Ozone
- More information
- Petrol (unleaded)
- More information
- Phosgene
- More information
- Phosphine
- More information
- Propane
- More information
- Propylene
- More information
- Propylene oxide
- More information
- Silane
- More information
- Styrene
- More information
- Sulphur dioxide
- More information
- Tetrahydrofuran
- More information
- Tetrahydrothiophene
- More information
- Toluene
- More information
- Triethylamine
- More information
- Trimethylamine (anhydrous)
- More information
- Vinyl chloride
- More information
- 1-Methoxy-2-propanol
- More information
- 1,3-Butadiene
- More information
- 2-Butanone
- More information
- 2-Methoxy-2-methyl-propane
- More information
- 2-Methyl-2-propanethiol
- More information
- 2-Propanol
- More information
- 2-Propenenitrile
- More information
- 3-Pentanol
- More information
Specifications 7
- Product
- Order number
- Dräger X-am 5000
- 8320000
- DrägerSensor Cat-Ex 125 PR
- 6812950
- DrägerSensor Cat-Ex 125 PR-Gas
- 6813080
- DrägerSensor XXS Amine
- 6812545
- DrägerSensor XXS CI2
- 6810890
- DrägerSensor XXS CO / H2 compensated
- 6811950
- DrägerSensor XXS CO HC
- 6812010
- DrägerSensor XXS CO LC
- 6813210
- DrägerSensor XXS CO LC / H2S LC
- 6813280
- DrägerSensor XXS CO2
- 6810889
- DrägerSensor XXS COCI2
- 6812005
- DrägerSensor XXS H2
- 6812370
- DrägerSensor XXS H2 HC
- 6812025
- DrägerSensor XXS H2S HC
- 6812015
- DrägerSensor XXS H2S LC
- 6811525
- DrägerSensor XXS HCN
- 6810887
- DrägerSensor XXS HCN PC
- 6813165
- DrägerSensor XXS NH3
- 6810888
- DrägerSensor XXS NO
- 6811545
- DrägerSensor XXS NO2
- 6810884
- DrägerSensor XXS NO2 LC
- 6812600
- DrägerSensor XXS O2
- 6810881
- DrägerSensor XXS O2 / CO LC
- 6813275
- DrägerSensor XXS O2 / H2S LC
- 6814137
- DrägerSensor XXS O2 100
- 6812385
- DrägerSensor XXS O2 PR
- 6800530
- DrägerSensor XXS Odorant
- 6812535
- DrägerSensor XXS OV
- 6811530
- DrägerSensor XXS OV-A
- 6811535
- DrägerSensor XXS Ozone
- 6811540
- DrägerSensor XXS PH3
- 6810886
- DrägerSensor XXS PH3 HC
- 6812020
- DrägerSensor XXS SO2
- 6810885
Related products
Additional products from the same category.

Dräger X-am 8000
1- to 7 gas detection devicefor clearance measurementdetection of toxic and combustible gases as well as vapours and oxygen

Calibration gas and accessories
Ensures safe operation and functionality of equipmentOffers various calibration gas options.Meets applicable regulations and codes of practice

Dräger Bump Test Station
Function testing for gas detection and warning devicesSimple, cordless and portable

Dräger Catalytic Ex-Sensors
monitoring of explosive mixtureshigh poisoning resistance to silicones and H2Scompatible with: X-am familymeasuring range: lower explosion limit up to 100 vol.-%